Control

Showing 97–108 of 115 results

  • IFD8520

    An addressable serial communication converter
    Sets up Modbus address
    Isolation in RS-485 channel (incl. power supply)

  • IFD9502

    Transmission method: CAN
    Electrical isolation: 500 VDC
    Connector: Removable, 5.08mm
    Transmission cables: 2 communication cables, 2 power cables, 1 shielded cable
    Serial baudrate: 125, 250, 500k bps
    Network voltage: 24 VDC (11 to 25 VDC)
    Current: 28 mA (typical), 125 mA impulse current (24 VDC)

  • IFD9503

    Supports CANopen protocol
    Connectable to all Delta@@s industrial automation products
    Isolation in CANopen channel (incl. power supply)
    Passed full compatibility test

  • IFD9506

    Isolation in RS-485 channel (incl. power supply)
    Supports Modbus TCP protocol
    Smart Monitor
    Supports webpage setup & on-line monitoring
    Serial Virtual COM available
    3 e-mail alarms (DI)

  • IFD9507

    Isolation in RS-485 channel (incl. power supply)
    Supports EtherNet/IP protocol
    Smart Monitor
    Supports webpage setup & on-line monitoring
    Serial Virtual COM available
    3 e-mail alarms (DI)

  • LCP-1FE

    Compliant with IEEE 802.3u
    Full duplex operation
    Supports IEEE 802.3x flow control
    DDM diagnosis function enhances transmission quality
    Duplex LC connector interface
    Hot-Pluggable for maximum flexibility
    TTL signal detect indicator
    Class 1 laser product (compliant with IEC 60825-1 and IEC 60825-2)
    Metal case for better EMI immunity
    Wide operating temperature

  • LCP-GbE

    Compliant with IEEE 802.3z
    Full duplex operation
    Supports IEEE 802.3x flow control
    DDM diagnosis function enhances transmission quality
    Duplex LC connector interface
    Hot-Pluggable for maximum flexibility
    TTL signal detect indicator
    Class 1 laser product (compliant with IEC 60825-1 and IEC 60825-2)
    Metal case for better EMI immunity
    Wide operating temperature

  • Motion Control Host PAC

    The MH1 Series supports Windows CE, Windows XP Embedded and Windows 7 Embedded operating systems and allows real-time applications running on OSs such as RTX Runtime. It also supports various software libraries for user selection.

  • Motion Control Host PAC

    The MH1 Series supports Windows CE, Windows XP Embedded and Windows 7 Embedded operating systems and allows real-time applications running on OSs such as RTX Runtime. It also supports various software libraries for user selection.

  • RTU-485

    Supports Modbus protocol
    Connectable to 8 DVP-S series analog I/O modules
    Connectable to 256 points of digital I/O modules
    Max. baudrate: 115.2k bpsk

  • RTU-DNET

    Supports DeviceNet protocol
    Connectable to 8 DVP-S series analog I/O modules
    Connectable to 256 points of digital I/O modules
    The RS-485 port is connectable to max. 8 Modbus slaves
    Max. baudrate: 500k bps

  • RTU-EN01

    A Modbus TCP slave
    Connectable to 8 DVP-S series analog I/O modules
    Connectable to 256 points of digital I/O modules
    The RS-485 port is connectable to max. 32 Modbus slaves
    Smart PLC if-then function
    Smart Monitor
    Supports webpage setup & on-line monitoring
    Serial Virtual COM available